• English
    X

    Google Translate Disclaimer

    The Maryland Department of Information Technology (“DoIT”) offers translations of the content through Google Translate. Because Google Translate is an external website, DoIT does not control the quality or accuracy of translated content. All DoIT content is filtered through Google Translate which may result in unexpected and unpredictable degradation of portions of text, images and the general appearance on translated pages. Google Translate may maintain unique privacy and use policies. These policies are not controlled by DoIT and are not associated with DoIT’s privacy and use policies. After selecting a translation option, users will be notified that they are leaving DoIT’s website. Users should consult the original English content on DoIT’s website if there are any questions about the translated content.

    DoIT uses Google Translate to provide language translations of its content. Google Translate is a free, automated service that relies on data and technology to provide its translations. The Google Translate feature is provided for informational purposes only. Translations cannot be guaranteed as exact or without the inclusion of incorrect or inappropriate language. Google Translate is a third-party service and site users will be leaving DoIT to utilize translated content. As such, DoIT does not guarantee and does not accept responsibility for, the accuracy, reliability, or performance of this service nor the limitations provided by this service, such as the inability to translate specific files like PDFs and graphics (e.g. .jpgs, .gifs, etc.).

    DoIT provides Google Translate as an online tool for its users, but DoIT does not directly endorse the website or imply that it is the only solution available to users. All site visitors may choose to use alternate tools for their translation needs. Any individuals or parties that use DoIT content in translated form, whether by Google Translate or by any other translation services, do so at their own risk. DoIT is not liable for any loss or damages arising out of, or issues related to, the use of or reliance on translated content. DoIT assumes no liability for any site visitor’s activities in connection with use of the Google Translate functionality or content.

    The Google Translate service is a means by which DoIT offers translations of content and is meant solely for the convenience of non-English speaking users of the website. The translated content is provided directly and dynamically by Google; DoIT has no direct control over the translated content as it appears using this tool. Therefore, in all contexts, the English content, as directly provided by DoIT is to be held authoritative.

    Semi-Volatile Section

    ​​​Purpose

    The SEMI-VOLATILE ORGANICS SECTION performs the analyses of pesticides, herbicides, semi-volatile organic compounds and polychlorinated biphenyls (PCBs) in drinking water, wastewater, groundwater, aquatic tissues, hazardous wastes, soils, sediments, sludges, leachates, and in consumer products for possible tampering or adulteration. Analysis of multi-media samples is carried out using capillary column gas chromatographs equipped with electron capture detectors (GC/ECD) or mass spectrometers (GC/MS), and high performance liquid chromatographs (HPLC) equipped with fluorescence detectors.
     

    Instrumentation

    Analysis of multi-media samples is carried out using capillary column gas chromatographs equipped with mass spectrometer detector (GC/MS) and Electron Capture detector (GC/ECD) A typical GC/ECD & GC/MS is shown below: Most methods involves a lengthy extraction process to derivatize the sample to a thermally stable volatile form before the analyses by GC. 
    • Agilent GC/ECD
    • Agilent GC/MS
    • HPLC

    Gas Chromatograph – Electron Capture Detector (GC/ECD) 
    The ECD or electron capture detector measures electron-absorbing components (usually halogenated) by creating an electrical field in which molecules exiting the GC column can be detected by the drop in current in the field. The ECD uses a radioactive beta particle (electron) emitter in conjunction with a makeup gas flowing through the detector chamber.

    Gas Chromatograph – Mass Spectrometer (GC/MS)
    Gas chromatography–mass spectrometry (GC-MS) is a method that combines two techniques to form a single method of analyzing samples. Gas-chromatography separates the elements of a sample and the mass-spectrometry characterizes each element making it possible to qualitatively and quantitatively analyze samples. The GC-MS is a system tailored to meet the rigorous demands for scientist in both routine analysis and research.

    Elements Routinely Analyzed

    The laboratory analyzes pesticides, herbicides, haloacetic acids, PCBs, semi-volatile organic compounds in drinking water by various EPA. Pesticides, PCBs and semi-volatiles in wastewater, soil, hazardous waste, sediments, and sludge are analyzed by EPA method 8270 in support of State and federal environmental regulations.

    *Pending EPA Provisional Certifications
    ** Glass vials must have Teflon-lined septum caps; glass bottles must have Teflon-lined caps
    NA = not applicable 

    Potential Health Concerns and Environmental Effects 

    SVOCs include a variety of chemicals, which can have short or long term adverse health effects which can range from being highly toxic to having no known health effects. Some are suspected to be cancer causing in humans and some are known to be carcinogenic in animals and humans.